LUGB Vortex Flow Meter
LUGB Vortex Flow Meter with Temperature and Pressure Compensation
LUGB vortex flow meter with temperature and pressure compensation for gas and steam measurement where density changes must be corrected.
Specifications
- Series
- LUGB vortex flow meter
- Type
- With temperature / pressure compensation
- Medium
- Gas, liquid, steam
- Nominal Sizes
- Flange DN15 to DN300 (shown to DN350)
- Compensation Options
- A none; B temperature; C pressure; D temp+pressure integrated; E temp+pressure split
- Accuracy
- Liquid class 1; gas class 1.5
- Medium Temperature
- Standard -25 to +80 °C; high temp -25 to +250 °C or -25 to +300 °C
- Pressure Rating
- 1.6 MPa / 2.5 MPa / 4.0 MPa
- Body Material
- Stainless steel 304; converter housing aluminium alloy
- Output
- Pulse and 4-20 mA; RS485 available
- Protection
- IP65
- Liquid Flow Range DN15
- 0.3–3 m³/h
- Liquid Flow Range DN20
- 0.5–5 m³/h
- Liquid Flow Range DN25
- 1.2–12 m³/h
- Liquid Flow Range DN32
- 1.5–15 m³/h
- Liquid Flow Range DN40
- 2.2–22 m³/h
- Liquid Flow Range DN50
- 4–40 m³/h
- Liquid Flow Range DN65
- 6–60 m³/h
- Liquid Flow Range DN80
- 9–90 m³/h
- Liquid Flow Range DN100
- 14–140 m³/h
- Liquid Flow Range DN125
- 22–220 m³/h
- Liquid Flow Range DN150
- 35–350 m³/h
- Liquid Flow Range DN200
- 65–650 m³/h
- Liquid Flow Range DN250
- 120–1200 m³/h
- Liquid Flow Range DN300
- 180–1800 m³/h
- Gas Flow Range (working) DN15
- 5–30 m³/h
- Gas Flow Range (working) DN20
- 5.5–56 m³/h
- Gas Flow Range (working) DN25
- 10.2–80 m³/h
- Gas Flow Range (working) DN32
- 15–150 m³/h
- Gas Flow Range (working) DN40
- 22–220 m³/h
- Gas Flow Range (working) DN50
- 35–350 m³/h
- Gas Flow Range (working) DN65
- 60–600 m³/h
- Gas Flow Range (working) DN80
- 90–900 m³/h
- Gas Flow Range (working) DN100
- 140–1400 m³/h
- Gas Flow Range (working) DN125
- 220–2200 m³/h
- Gas Flow Range (working) DN150
- 300–3000 m³/h
- Gas Flow Range (working) DN200
- 550–5500 m³/h
- Gas Flow Range (working) DN250
- 1100–11000 m³/h
- Gas Flow Range (working) DN300
- 1500–15000 m³/h
- Saturated Steam Capacity
- Pressure-specific: 0.1–4.3 MPa table, DN25–200 (kg/h); state line pressure for the exact range
Where the Compensated LUGB Fits
Vortex meters measure volumetric flow, but gas and steam density changes with pressure and temperature. The compensated LUGB corrects for that so the reading reflects standard volumetric or mass flow, which matters for steam billing and gas measurement where conditions vary.
Construction and Specifications
The model code offers five compensation options: A none, B temperature, C pressure, D temperature and pressure integrated, and E temperature and pressure split. Choose the option that matches how your process conditions vary.
Flanged sizes run from DN15 to DN300, with DN350 shown. Accuracy is class 1 for liquid and class 1.5 for gas. Medium temperature versions cover -25 to +80 °C standard duty and -25 to +250 °C or -25 to +300 °C high temperature. Pressure ratings are 1.6 MPa, 2.5 MPa or 4.0 MPa.
The body is stainless steel 304 with an aluminium alloy converter housing and IP65 protection. Output is pulse or 4-20 mA, with RS485 available.
Ordering Guidance
Tell us the medium, pipe size, the normal and maximum pressure and temperature, and the flow range. We will confirm whether temperature, pressure or combined compensation is required and select the matching model code option.
What to Include in Your Inquiry
When requesting a quotation for an LUGB vortex flow meter, please provide: the medium (liquid, gas or steam); for steam, whether it is saturated or superheated and the line pressure; pipe DN; minimum, normal and maximum flow; operating pressure and temperature; the compensation option (A none, B temperature, C pressure, D integrated temperature-pressure, E separate temperature-pressure); output and power supply; pipe orientation; and the available straight-run lengths.