LD Electromagnetic Flow Meter
Split Type LD Electromagnetic Flow Meter
Split type (remote) LD electromagnetic flow meter with separated converter, DN15 to DN2200, for conductive liquids.
Specifications
- Series
- LD electromagnetic flow meter
- Type
- Split type (separated / remote converter)
- Nominal Sizes
- DN15 to DN2200
- Medium
- Conductive liquid
- Conductivity
- ≥ 5 µS/cm
- Accuracy
- ±0.5% to ±1.0% (depending on configuration)
- Flow Velocity
- 0.3-5 m/s (extended range shown to 10 m/s)
- Medium Temperature
- Split type ≤ 150 °C (rubber ≤ 80 °C)
- Pressure Rating
- 0.25–4.0 MPa (by size)
- Electrodes
- 316L, Hb, Hc, Ti, Ta, Pt
- Liners
- Chloroprene rubber, polyurethane, PTFE, PFA, F46
- Output
- 4-20 mA / frequency or pulse / RS485
- Power Supply
- 220 VAC or 24 VDC
- Protection
- IP65, IP67, IP68 (split type IP68)
- Flow Range DN15
- 0.32–3.2 m³/h (working pressure 4.0 MPa)
- Flow Range DN20
- 0.56–5.6 m³/h (working pressure 4.0 MPa)
- Flow Range DN25
- 0.9–9 m³/h (working pressure 4.0 MPa)
- Flow Range DN32
- 1.5–15 m³/h (working pressure 4.0 MPa)
- Flow Range DN40
- 2.3–23 m³/h (working pressure 4.0 MPa)
- Flow Range DN50
- 3.5–35 m³/h (working pressure 4.0 MPa)
- Flow Range DN65
- 6–60 m³/h (working pressure 4.0 MPa)
- Flow Range DN80
- 9–90 m³/h (working pressure 4.0 MPa)
- Flow Range DN100
- 14–140 m³/h (working pressure 1.6 MPa)
- Flow Range DN125
- 20–200 m³/h (working pressure 1.6 MPa)
- Flow Range DN150
- 30–300 m³/h (working pressure 1.6 MPa)
- Flow Range DN200
- 56–560 m³/h (working pressure 1.0 MPa)
- Flow Range DN250
- 90–900 m³/h (working pressure 1.0 MPa)
- Flow Range DN300
- 125–1250 m³/h (working pressure 1.0 MPa)
- Flow Range DN350
- 175–1750 m³/h (working pressure 1.0 MPa)
- Flow Range DN400
- 230–2300 m³/h (working pressure 1.0 MPa)
- Flow Range DN450
- 290–2900 m³/h (working pressure 1.0 MPa)
- Flow Range DN500
- 350–3500 m³/h (working pressure 1.0 MPa)
- Flow Range DN600
- 510–5100 m³/h (working pressure 1.0 MPa)
- Flow Range DN700
- 700–7000 m³/h (working pressure 1.0 MPa)
- Flow Range DN800
- 900–9000 m³/h (working pressure 1.0 MPa)
- Flow Range DN900
- 1150–11500 m³/h (working pressure 1.0 MPa)
- Flow Range DN1000
- 1400–14000 m³/h (working pressure 1.0 MPa)
- Flow Range DN1200
- 2000–20000 m³/h (working pressure 0.6 MPa)
- Flow Range DN1400
- 2800–28000 m³/h (working pressure 0.6 MPa)
- Flow Range DN1600
- 3600–36000 m³/h (working pressure 0.6 MPa)
- Flow Range DN1800
- 4600–46000 m³/h (working pressure 0.6 MPa)
- Flow Range DN2000
- 5600–56000 m³/h (working pressure 0.6 MPa)
- Flow Range DN2200
- 6800–68000 m³/h (working pressure 0.25 MPa)
- Range Table Note
- Water-referenced conditions per catalog; working pressure by size
Where the Split Type LD Fits
The split type LD separates the sensor from the converter. The sensor covers DN15 to DN2200 and measures conductive liquids, with the same electrode, liner and output options as the integrated version.
Construction and Specifications
Medium conductivity must be at least 5 µS/cm. Accuracy is ±0.5% to ±1.0% by configuration, with a velocity range of 0.3 to 5 m/s and an extended range shown to 10 m/s.
Because the converter is remote, the split type accepts a higher medium temperature than the integrated type: up to 150 °C, or up to 80 °C with rubber liners. Electrode materials are 316L, Hb, Hc, Ti, Ta and Pt, and liner options are chloroprene rubber, polyurethane, PTFE, PFA and F46.
Output options are 4-20 mA, frequency or pulse, and RS485. Power supply is 220 VAC or 24 VDC, and IP65, IP67 and IP68 protection are available; the split type can reach IP68.
Ordering Guidance
Tell us the pipe size, medium and conductivity, flow range, pressure, and how far the converter will be mounted from the sensor. Provide any output requirement, and we will confirm the electrode, liner and cable configuration.
What to Include in Your Inquiry
When requesting a quotation for an LD electromagnetic flow meter, please provide: the liquid name and chemistry (for liner and electrode selection); confirmation that conductivity is at least 5 µS/cm; minimum, normal and maximum flow; pipe DN; medium temperature; working pressure; required output (4-20 mA, pulse or RS485); power supply (220 VAC or 24 VDC); integrated or split type (and cable length if split); and the flange standard.